Knauf Insulation Jet Stream® Ultra Blowing Insulation

Description
Knauf Insulation Jet
Stream® ULTRA Fiber Glass
Blowing Insulation is an unbonded, virgin fibrous glass blowing
insulation designed with optimal thermal properties and excellent
coverage and blowing characteristics.
Application
Knauf Insulation Jet Stream
ULTRA Fiber Glass Blowing Insulation is
installed in open attics of both new and existing structures and/or
in closed cavity applications with the BIBS system (Blow-in-Blanket
System) in which ventilation is not required. Jet Stream
ULTRA, when used in closed cavity
applications is BIBS approved and can only be installed by BIBS
certified installers to ensure the highest quality installed
performance. Loose fill blowing insulation is intended for use
where pneumatically installed insulation is most
cost-effective.
Features and
Benefits
Excellent Thermal
Performance
- Fills all gaps and voids, creating a thermal barrier
against outside air and better temperature control.
- Resists heat flow with an
R-value of:
- R-15 in 2 x 4 construction
- R-23 in 2 x 6 construction
Convenient
- One product, one inventory, two applications.
Energy
Conservation
- Reduces fuel usage and utility bills for heating and air
conditioning.
Sustainable
- Each bag contains the equiivalent of over 30 recycled bottles,
with a minimum of 61.9% post consumer recycled glass content.
Noise Reduction
- Improves Sound Transmission Class
(STC) ratings by 4 to 10 points.
Installation
Permanence
- Non-combustible,
non-corrosive.
- Will not rot, mildew or
deteriorate.
Thermal Performance
Jet Stream
ULTRA Blowing Insulation provides you a
choice of R-values based on the installed thickness and installed
weight per square foot. The tables below show the minimum
requirements for obtaining the desired R-value.
The stated thermal resistance
(R-value) is provided by installing in accordance with the
manufacturer‘s instructions. The required number of bags per 1,000
sq. ft. of net area, at not less than the labeled minimum
thickness. Failure to install both the required number of bags and
at least the minimum thickness will result in lower insulation
R-values.
Field blending of this product with
other loose fill insulation or application of this product in
conjunction with adhesive or binder systems may affect its thermal
performance and is not recommended by the manufacturer.
Specification
Compliance
- ASTM C 764; Type I
- HH-I-1030B; Class B
- GREENGUARD Environmental
Institute™
- GREENGUARD For Children and
SchoolsSM
Knauf Jet Stream
ULTRA Fiber Glass Blowing Insulation is
manufactured with a minimum of 40% post consumer recycled
glass.
Technical
Data
Surface Burning
Characteristics
- Does not exceed 25 Flame
Spread, 50 Smoke Developed when tested in accordance with ASTM E 84
and CAN 4-S102.2.
Critical Radiant Flux (ASTM E
970)
Moisture Vapor Sorption (ASTM
C 1104)
Corrosion (ASTM C
764)
- No greater than sterile
cotton.
Microbial Growth (ASTM C
1338)
- Does not support microbial
growth.
Non-Combustibility (ASTM E
136)
- No temperature rise above 54°F
(30°C).
Equipment
Required
To achieve labeled R-value, this
product must be applied with a pneumatic blowing machine and a
corrugated hose with a minimum ¼" internal corrugation, a minimum
length of 150' and a diameter of at least 3". Coils in the hose
should not be less than 36" in diameter. Acceptable material feed
rate is 5-35 lbs./minute. The recommended feed rate is 15-25
lbs./minute. For closed cavilty applications, netting must be
applied.
Packaging
- Jet Stream
ULTRA Blowing Insulation is pack- aged in
a strong, white poly bag that offers excel- lent protection from
abuse, dust and moisture.
- Knauf Insulation packages are
lightweight, stack without slipping and are easy to handle and
store.
Fiber Glass and
Mold
Fiber glass insulation will not
sustain mold growth. However, mold can grow on almost any material
when it becomes wet and contaminated. Carefully inspect any
insulation that has been exposed to water. If it shows any sign of
mold, it must be discarded. If the material is wet, but shows no
evidence of mold, it should be dried rapidly and thoroughly. If it
shows signs of facing degradation from wetting, it should be
replaced.
Open Attic
Application
| R-Value* |
Bags per
1,000 SF |
Maximum
Coverage |
Minimum
Weight |
Intial Installed
Thickness |
Minimum
Settled
Thickness** |
|
|
|
|
|
|
To obtain a
thermal resistance
(R-Value) of: |
The number of
bags/1,000
sq. ft. of net
area should
not be less than: |
Contents of one bag
should not cover
more than: |
The weight per sq. ft.
of installed insulation
should not be less than: |
Installed insulation
thickness should
not be less than: |
Installed insulation
thickness should
not be less than: |
| R-60 |
29.7 |
33.6 SF |
.952 lbs. |
19.750" |
19.750" |
| R-49 |
23.5 |
42.5 SF |
.753 lbs. |
16.375" |
16.375" |
| R-44 |
20.9 |
47.8 SF |
.670 lbs. |
14.875" |
14.875" |
| R-38 |
17.8 |
56.2 SF |
.569 lbs. |
13.000" |
13.000" |
| R-30 |
13.6 |
73.3 SF |
.437 lbs. |
10.375" |
10.375" |
| R-26 |
11.8 |
85.0 SF |
.377 lbs. |
9.125" |
9.125" |
| R-22 |
9.8 |
102.2 SF |
.313 lbs. |
7.750" |
7.750" |
| R-19 |
8.4 |
119.3 SF |
.268 lbs. |
6.750" |
6.750" |
| R-13 |
5.7 |
175.3 SF |
.183 lbs. |
4.750" |
4.750" |
| R-11 |
4.7 |
210.8 SF |
.152 lbs. |
4.000" |
4.000" |
|
|
|
|
|
|
Bag Net Weight - Nominal 32 lbs., Minimum 31 lbs.
Coverage and installation data were determined using a
Volu-Matic® II blowing machine in third gear with 13"
gate opening, 2.0 psi air pressure, 150' of 3" diameter
internally-corrugated hose.
* "R" means resistance to heat flow. The higher the R-value, the
greater the insulating power. To get the marked R-value, it is
essential that this insulation be installed properly. If you do it
yourself, get instructions and follow them carefully. Instructions
do not come with this package.
**Based on Third Party 2-year settling study, the predicted
settlement over a 20-year period would be 1 percent or less. This
amount of settling is thermally insignificant. Therefore, the
installed and settled thicknesses are effectively the same.
Volu-Matic® II is a registered trademark of
Unisul.
Cavity Wall Application
| Framing |
Cavity Depth |
R-Value* |
Density |
Bags per 1000 SF |
Maximum Coverage per
bag |
Net Minimum
Thickness** |
| |
|
To obtain an insulation resistance
of |
|
The number of bags per 1000 SF of
new area should not be less than: |
Contents of this bag should not
cover more than: |
The weight pwe aquare foot of
installed insulation should not be less than: |
| 2"x4" |
3.50" |
R-15 |
1.8lbs/cuft |
16.4 bags |
61.0 SF |
0.525 lbs |
| 2"x6" |
5.50" |
R-23 |
1.8lbs/cuft |
25.8 bags |
38.8 SF |
0.825 lbs |
| 2"x8" |
7.25" |
R-31 |
1.8lbs/cuft |
34.0 bags |
29.4 SF |
1.088 lbs |
| 2"x10" |
9.25 |
R-39 |
1.8lbs/cuft |
43.4 bags |
23.1 SF |
1.388 lbs |
Notes:
The chemical and physical properties
of Knauf Jet Stream ULTRA Blowing
Insulation represent typical average values determined in
accordance with accepted test methods.
The data is supplied as technical
service and is subject to change without notice. References to
numerical flame spread ratings are not intended to reflect hazards
presented by these or any other materials under actual fire
conditions.
Check with your Knauf Insulation sales representative to assure
information is current.